News Center

How to adjust the parameters of hot runner for wire drawing and casting?

Date:2026-11-16 Hits:4

Principle: If the molten material in the sprue has not yet solidified and there is residual pressure inside the runner, and the mold is opened and pulled open, it is called wire drawing; Dropping during shutdown/material storage is salivation. The parameter adjustment sequence is: temperature control → pullback → pressure maintenance → cooling, only changing one parameter at a time.


##  ✅  Open hot runner (with a pointed spout that is easiest to draw)


1. * * Hot nozzle temperature (priority adjustment)**

Lower the front end of the hot nozzle by 5-10 ℃, do not lower it too much at once; The temperature of the splitter plate can remain unchanged. Objective: Quickly establish a layer of cold material layer sealing glue at the gate position, without blocking the gate and causing insufficient injection.


> 

>Attention: First confirm that the thermocouple is not drifting and the displayed temperature is not equal to the actual tip temperature.


2. * * Pull back after injection (loosen/reverse)**

Increase the pullback distance before material storage and remove residual pressure inside the hot runner; One of the most effective ways to improve drooling is to add a * * pullback delay * * and stop at the end of pressure maintenance before pulling back. Do not pull back too much, as it can easily suck in air and bubbles.

3. * * Pressure holding parameters**

Reduce the holding pressure and shorten the holding time; The holding pressure is too high, and the gate is constantly pushed by high-pressure melt, making it difficult to solidify.

4. Cooling and mold temperature**

Extend the cooling time appropriately to ensure the solidification of the gate before mold opening; If the mold temperature in the sprue area is too high, the mold temperature should be lowered. It is crucial for the sprue water channel to be unobstructed.

5. Plasticization parameters**

Reduce back pressure, decrease screw speed, reduce shear heat, and avoid excessive material temperature; The sufficient drying of raw materials and the generation of gas during decomposition can also exacerbate the casting process.


##  ✅  Needle valve hot runner (wire drawing mostly involves timing and sealing issues)


Needle valve is normally mechanically cut off by the valve needle, and it is difficult to cure wire drawing simply by adjusting the process:


1. * * Valve closing timing (top priority)**

Close the needle after the pressure holding is completed and the molten material in the gate has cooled down; **Close the valve in advance (50-150ms), do not wait until before mold opening to close the valve; If the valve needle is closed too late and the gate is still in a molten state, it will draw wire.

2. * * Drive pressure**

Do not blindly increase the cylinder/oil pressure, as excessive pressure can easily damage the sealing surface; Just seal the gate with pressure.

3. Process assistance: also cooperate with small temperature reduction of the heating nozzle and reasonable retraction.


> 

>If the timing is adjusted and the wire is still drawn, priority should be given to checking whether the valve needle and gate seat are worn, and whether there are gaps in the sealing surface. Hardware wear cannot be controlled by adjusting the parameters.


##  ⚠️  Key points for avoiding pitfalls


1. Do not rely on sudden cooling and hard pressing to draw, as it is easy for the gate to block, short shot, and poor color change;

2. The risk of drawing and casting low viscosity materials such as PP, PE, PET, and PC is much higher than that of ABS;

3. Shutdown drooling: prioritize retraction+appropriately reduce the insulation temperature of the heating nozzle;

4. If the parameter adjustment is invalid, check the hardware again: the gate is too large, the nozzle tip is worn, the thermal insulation layer of the hot nozzle is ineffective, and the gate lacks cooling inserts.


##  ✅  Quick debugging sequence (directly used in the workshop)


1. Reduce the temperature of the heating nozzle to 5 ℃ → Trial mold

2. Increase the retraction distance and add retraction delay

3. Reduce the holding pressure and shorten the holding time

4. Extend cooling

5. For needle valve models, adjust the valve closing timing directly first